Wednesday, March 4, 2026

Optimizing Cooling Tower Performance by Improving Water Quality with Environmentally Friendly AOP Technology

Cooling towers are important and vital equipments for the operations of various processing industries at large. This cooling process is very important for the processing industry, chemical industry, oil and gas industry (oil refineries and petrochemicals), biofuel and biorefinery industries, power plants (fossil fuel and biomass), geothermal and large-scale (hyperscale) data centers. With the process conditions achieved, the industry can produce products that are economical/efficient and stable.

The cooling medium in the industry or factory is water, and the water is cooled in a cooling tower. And air from the atmosphere is used to cool warm water from industrial or factory processes through this cooling tower. This results in direct contact between air from the atmosphere and the warm water to be cooled. This is a source of pollution for the cooling tower water. A certain amount of additional water (make-up water) also needs to be added to replace lost water such as blow down, leaks and so on.

With continuous 24-hour operation for almost a whole year with a large volume of circulating cooling water, up to thousands of tonnes/hour, it is certainly not a simple matter to be able to maintain good and stable water quality. If water quality cannot be maintained, a number of serious problems will arise. A number of problems for cooling tower operations such as corrosion, scale, layers formed by green algae, organic materials and a number of micro organisms will reduce the performance of the cooling tower. If this happens, heat exchange will be disrupted and energy requirements for cooling tower operations will increase. When the cooling process does not work as it should, it will also affect product quality and the durability of production equipment, in the extreme case, if the cooling tower does not function, the industry or factory will stop operating (shut down).

If the cooling tower is damaged or has low efficiency, such as due to scale, there will be a low heat dissipation effect and a lot of energy loss. Then rust causes the pipe to become brittle and leak, resulting in a short life span for the pipe. Then the appearance of green algae, moss and mud from the accumulation of organic material, these things will disrupt the flow of water and even block pipes and valves. Another nuisance is the presence of bacteria and especially legionella (pathogenic bacteria that cause legionellosis) which causes various health problems.

Cold water as the output/product of the cooling tower will be used as a cooling medium in industry or factories such as condensers or other heat exchangers. The layer of fouling formed by scale on the surface of the heat exchanger ultimately reduces the overall heat transfer coefficient. In general, about 15% of energy is lost each year due to a decrease in heat transfer efficiency caused by fouling. Therefore, it is necessary to replace the pipes periodically every 3 to 5 years, and that is not a cheap cost. Even if the fouling problem is not controlled, heat loss can reach up to 70% after five years of operation.

If a problem occurs, repairs need to be carried out and often cooling tower repairs are expensive. A number of improvements/repairs to the cooling tower include structural repairs, replacement of mechanical components, drift eliminators, water distribution and fill types. Apart from the design problems of the cooling tower equipment manufacturers, water quality problems greatly affect the performance and lifespan of the equipment. This means that one solution is that efforts to maintain water quality must be maximized.

AOP (advanced oxidation process) technology has become the focus of developed countries to maximize water quality, including water as a cooling medium that is processed in cooling towers. AOP technology provides complete sterilization without leaving toxic residues and exhibits much stronger oxidizing power than conventional oxidants such as chlorine, chlorine dioxide and potassium permanganate. AOP technology specifically designed for reaction speed and intensity will be very effective for this purpose.

Compared to chemical treatment, although chemical treatment is still commonly used, there are restrictions due to environmental pollution and formaldehyde production, as well as because workers are exposed to serious dangers. As the restrictions on environmental pollution by respective governments become increasingly stringent, the use of chemicals will become increasingly restricted. Several developed countries are starting to control the addition of chemicals. The Singapore government has banned the addition of chemicals to cooling towers since 2008.

If you are interested in knowing AOP technology and its application for cooling tower water conditioners, please contact: eko.sbs@gmail.com 

Sunday, January 4, 2026

Energy Sources for Data Centers: Between Growth and Sustainability and the Role of Bioenergy

Data centers are physical facilities that house computer systems and related infrastructure, such as servers and storage, used to store and process data. They form the foundation of a nation's computing power and are a core dependency in building large-scale Artificial Intelligence (AI). AI data centers, in particular, are particularly energy-intensive. According to the International Energy Agency (IEA), a typical AI data center currently uses as much energy as 100,000 households, while large AI centers currently consume about 20 times that amount (2 million households).

The computing power needed to support AI growth is also doubling approximately every 100 days. For example, Malaysia, it is not surprising that data center energy consumption in Malaysia is projected to soar to more than 5,000 MW by 2035, which is 40 percent of Peninsular Malaysia's current power capacity, or 11.1 percent of Malaysia's projected power capacity in 2035. Meanwhile, in Indonesia. Meanwhile, the projection of data center electricity consumption in Indonesia has increased significantly, predicted to reach 5,200 MW in 2034 and could even reach 12,000 MW in 2033. And the current capacity in 2025 is only around 274 MW and with a predicted growth of 16.8% per year, it can reach the target of >2,000 MW in 2029.

There are at least two main drivers of growth in the data center industry. First, demand-side factors include the growth of cloud computing and AI, along with the increasing global demand for data storage and processing capacity for everyday tasks like social networking, e-commerce, and data storage. Second, supply-side factors include the availability of resources such as electricity and water, fiber optic connectivity, and land availability.

In the growing data center industry, high or wasteful energy consumption has contributed to rising electricity prices for residents and small businesses. Each country should learn from these case studies as they strive to strike a balance between growth and sustainability. For example, in Georgia, the fastest-growing data center market in the country, Georgia Power reports that 80 percent of the projected 8,200 MW increase in energy demand by 2030 is related to planned data centers opening in the state. To address the increased demand, base electricity rates have been raised and new nuclear power plant (NPP) are under construction.

Georgia is an attractive market for data centers, given its relatively low electricity prices, with industrial electricity rates about 42 percent below the US national average. Significant tax relief was also promised, with at least $163 million in state collections eliminated and local sales tax annually starting in 2022. However, starting in 2023, the average Georgia Power residential customer will pay $43 more per month following a base rate increase. To address this challenge, a Senate bill was introduced to protect residential and commercial customers from higher electricity bills due to the utility's significant investment in AI-powered energy needs.

Efforts to address the increasing energy demand for data centers while reducing their environmental impact are necessary. Typical approaches include optimizing Power Use Effectiveness (PUE) and related metrics, as well as shifting to renewable energy. The use of renewable energy for data centers remains limited, or even at a small capacity of less than 5%. Renewable energy sources still prioritize solar and intermittent wind.

Industry participants also state that the intermittent nature of solar energy (at least without a well-developed battery storage system) does not make it an ideal energy source for data centers, given the need to keep data centers running 24/7. With limited solar generating capacity, data centers often rely on backup diesel generators. While renewable diesel (biodiesel and green diesel) is an available option, there are currently no regulations encouraging this transition.

Biomass as an energy source, or bioenergy, for data centers is still very limited. This biomass can be used directly in biomass power plants, where the CFB type is very common, or through co-firing in coal-fired power plants. Furthermore, biomass can be utilized as an energy source and biochar production through pyrolysis technology, as is the case with this US company. The syngas from pyrolysis serves as a carbon-neutral energy source, and biochar is the primary product for carbon capture and sequestration (CCS), resulting in carbon-negative operations. 